Seguir
Chris James
Chris James
Research, Cochlear France SAS
Dirección de correo verificada de cochlear.com
Título
Citado por
Citado por
Año
The size of the cochlea and predictions of insertion depth angles for cochlear implant electrodes
B Escudé, C James, O Deguine, N Cochard, E Eter, B Fraysse
Audiology and Neurotology 11 (Suppl. 1), 27-33, 2006
4342006
Preservation of residual hearing with cochlear implantation: how and why
C James, K Albegger, R Battmer, S Burdo, N Deggouj, O Deguine, ...
Acta oto-laryngologica 125 (5), 481-491, 2005
3202005
Residual hearing conservation and electroacoustic stimulation with the nucleus 24 contour advance cochlear implant
B Fraysse, ÁR Macías, O Sterkers, S Burdo, R Ramsden, O Deguine, ...
Otology & neurotology 27 (5), 624-633, 2006
2752006
Consensus panel on a cochlear coordinate system applicable in histologic, physiologic, and radiologic studies of the human cochlea
BM Verbist, MW Skinner, LT Cohen, PA Leake, C James, C Boëx, ...
Otology & neurotology 31 (5), 722-730, 2010
2322010
European multi-centre study of the Nucleus Hybrid L24 cochlear implant
T Lenarz, C James, D Cuda, A Fitzgerald O’Connor, B Frachet, JHM Frijns, ...
International Journal of Audiology 52 (12), 838-848, 2013
1562013
Comparison of three types of French speech-in-noise tests: A multi-center study
S Jansen, H Luts, KC Wagener, B Kollmeier, M Del Rio, R Dauman, ...
International Journal of Audiology 51 (3), 164-173, 2012
1562012
Adaptive dynamic range optimization for cochlear implants: a preliminary study
CJ James, PJ Blamey, L Martin, B Swanson, Y Just, D Macfarlane
Ear and hearing 23 (1), 49S-58S, 2002
1272002
Partial deafness treatment with the nucleus straight research array cochlear implant
H Skarzynski, A Lorens, M Matusiak, M Porowski, PH Skarzynski, ...
Audiology and Neurotology 17 (2), 82-91, 2012
1202012
Combined electroacoustic stimulation in conventional candidates for cochlear implantation
CJ James, B Fraysse, O Deguine, T Lenarz, D Mawman, Á Ramos, ...
Audiology and Neurotology 11 (Suppl. 1), 57-62, 2006
1192006
How much residual hearing is ‘useful’for music perception with cochlear implants?
F El Fata, CJ James, ML Laborde, B Fraysse
Audiology and Neurotology 14 (Suppl. 1), 14-21, 2009
1072009
Clinical investigation of the Nucleus Slim Modiolar Electrode
A Aschendorff, R Briggs, G Brademann, S Helbig, J Hornung, T Lenarz, ...
Audiol Neurotol 22, 169-179, 2017
982017
Quality of life and auditory performance in adults with asymmetric hearing loss
N Vannson, C James, B Fraysse, K Strelnikov, P Barone, O Deguine, ...
Audiology and Neurotology 20 (Suppl. 1), 38-43, 2015
952015
Monaural and binaural loudness measures in cochlear implant users with contralateral residual hearing
PJ Blamey, GJ Dooley, CJ James, ES Parisi
Ear and hearing 21 (1), 6-17, 2000
922000
Cochlear implantation with the nucleus slim straight electrode in subjects with residual low-frequency hearing
H Skarzynski, A Lorens, M Matusiak, M Porowski, PH Skarzynski, ...
Ear and hearing 35 (2), e33-e43, 2014
912014
Reliability of cone beam computed tomography in scalar localization of the electrode array: a radio histological study
M Marx, F Risi, B Escudé, I Durmo, C James, F Lauwers, O Deguine, ...
European Archives of Oto-Rhino-Laryngology 271, 673-679, 2014
762014
Speech prosody perception in cochlear implant users with and without residual hearing
M Marx, C James, J Foxton, A Capber, B Fraysse, P Barone, O Deguine
Ear and Hearing 36 (2), 239-248, 2015
682015
Voice discrimination in cochlear-implanted deaf subjects
Z Massida, P Belin, C James, J Rouger, B Fraysse, P Barone, O Deguine
Hearing research 275 (1), 120-129, 2011
612011
Effect of current level on electrode discrimination in electrical stimulation
CM McKay, A O’Brien, CJ James
Hearing research 136 (1-2), 159-164, 1999
611999
Very far-advanced otosclerosis: stapedotomy or cochlear implantation
MN Calmels, C Viana, G Wanna, M Marx, C James, O Deguine, B Fraysse
Acta oto-laryngologica 127 (6), 574-578, 2007
602007
Learning speech-in-noise discrimination in adult humans
KE Cainer, C James, R Rajan
Hearing research 238 (1), 155-164, 2008
582008
El sistema no puede realizar la operación en estos momentos. Inténtalo de nuevo más tarde.
Artículos 1–20