Seguir
Louis Archambault
Louis Archambault
Dirección de correo verificada de phy.ulaval.ca
Título
Citado por
Citado por
Año
Validation of GEANT4, an object‐oriented Monte Carlo toolkit, for simulations in medical physics
JF Carrier, L Archambault, L Beaulieu, R Roy
Medical physics 31 (3), 484-492, 2004
2282004
Measurement accuracy and Cerenkov removal for high performance, high spatial resolution scintillation dosimetry
L Archambault, AS Beddar, L Gingras, R Roy, L Beaulieu
Medical physics 33 (1), 128-135, 2006
2092006
Spectral method for the correction of the Cerenkov light effect in plastic scintillation detectors: a comparison study of calibration procedures and validation in Cerenkov …
M Guillot, L Gingras, L Archambault, S Beddar, L Beaulieu
Medical physics 38 (4), 2140-2150, 2011
1672011
Water‐equivalent dosimeter array for small‐field external beam radiotherapy
L Archambault, AS Beddar, L Gingras, F Lacroix, R Roy, L Beaulieu
Medical physics 34 (5), 1583-1592, 2007
1322007
Plastic scintillation dosimetry: Optimal selection of scintillating fibers and scintillators
L Archambault, J Arsenault, L Gingras, A Sam Beddar, R Roy, L Beaulieu
Medical physics 32 (7Part1), 2271-2278, 2005
1282005
Toward a real-time in vivo dosimetry system using plastic scintillation detectors
L Archambault, TM Briere, F Pönisch, L Beaulieu, DA Kuban, A Lee, ...
International Journal of Radiation Oncology* Biology* Physics 78 (1), 280-287, 2010
1182010
On the nature of the light produced within PMMA optical light guides in scintillation fiber-optic dosimetry
F Therriault-Proulx, L Beaulieu, L Archambault, S Beddar
Physics in Medicine & Biology 58 (7), 2073, 2013
1152013
A comparative study of small field total scatter factors and dose profiles using plastic scintillation detectors and other stereotactic dosimeters: the case of the CyberKnife
J Morin, D Béliveau‐Nadeau, E Chung, J Seuntjens, D Thériault, ...
Medical physics 40 (1), 011719, 2013
1152013
Exploration of the potential of liquid scintillators for real‐time 3D dosimetry of intensity modulated proton beams
S Beddar, L Archambault, N Sahoo, F Poenisch, GT Chen, MT Gillin, ...
Medical Physics 36 (5), 1736-1743, 2009
962009
Clinical prototype of a plastic water‐equivalent scintillating fiber dosimeter array for QA applications a
F Lacroix, L Archambault, L Gingras, M Guillot, AS Beddar, L Beaulieu
Medical physics 35 (8), 3682-3690, 2008
952008
Dosimetric performance and array assessment of plastic scintillation detectors for stereotactic radiosurgery quality assurance
JC Gagnon, D Thériault, M Guillot, L Archambault, S Beddar, L Gingras, ...
Medical physics 39 (1), 429-436, 2012
882012
Measuring output factors of small fields formed by collimator jaws and multileaf collimator using plastic scintillation detectors
DM Klein, RC Tailor, L Archambault, L Wang, F Therriault‐Proulx, ...
Medical physics 37 (10), 5541-5549, 2010
842010
Determination of the quenching correction factors for plastic scintillation detectors in therapeutic high-energy proton beams
LLW Wang, LA Perles, L Archambault, N Sahoo, D Mirkovic, S Beddar
Physics in Medicine & Biology 57 (23), 7767, 2012
802012
A new water‐equivalent 2D plastic scintillation detectors array for the dosimetry of megavoltage energy photon beams in radiation therapy
M Guillot, L Beaulieu, L Archambault, S Beddar, L Gingras
Medical physics 38 (12), 6763-6774, 2011
752011
Current status of scintillation dosimetry for megavoltage beams
L Beaulieu, M Goulet, L Archambault, S Beddar
Journal of Physics: Conference Series 444 (1), 012013, 2013
702013
Verification of proton range, position, and intensity in IMPT with a 3D liquid scintillator detector system
L Archambault, F Poenisch, N Sahoo, D Robertson, A Lee, MT Gillin, ...
Medical Physics 39 (3), 1239-1246, 2012
672012
Novel, full 3D scintillation dosimetry using a static plenoptic camera
M Goulet, M Rilling, L Gingras, S Beddar, L Beaulieu, L Archambault
Medical physics 41 (8Part1), 082101, 2014
662014
The robustness of dose distributions to displacement and migration of 125I permanent seed implants over a wide range of seed number, activity, and designs
L Beaulieu, L Archambault, S Aubin, E Oral, R Taschereau, J Pouliot
International Journal of Radiation Oncology* Biology* Physics 58 (4), 1298-1308, 2004
662004
Overview of Geant4 applications in medical physics
L Archambault, L Beaulieu, JF Carrier, F Castrovillari, S Chauvie, ...
2003 IEEE Nuclear Science Symposium. Conference Record (IEEE Cat. No …, 2003
662003
Characterizing the response of miniature scintillation detectors when irradiated with proton beams
L Archambault, JC Polf, L Beaulieu, S Beddar
Physics in Medicine & Biology 53 (7), 1865, 2008
632008
El sistema no puede realizar la operación en estos momentos. Inténtalo de nuevo más tarde.
Artículos 1–20