Seguir
Mike Tree
Mike Tree
Technical Lead at Corvid Technologies
Dirección de correo verificada de corvidtec.com - Página principal
Título
Citado por
Citado por
Año
Respiratory effects on Fontan circulation during rest and exercise using real-time cardiac magnetic resonance imaging
Z Wei, KK Whitehead, RH Khiabani, M Tree, E Tang, SM Paridon, ...
The Annals of Thoracic Surgery 101 (5), 1818-1825, 2016
552016
The advantages of viscous dissipation rate over simplified power loss as a Fontan hemodynamic metric
ZA Wei, M Tree, PM Trusty, W Wu, S Singh-Gryzbon, A Yoganathan
Annals of biomedical engineering 46, 404-416, 2018
352018
Can time-averaged flow boundary conditions be used to meet the clinical timeline for Fontan surgical planning?
ZA Wei, PM Trusty, M Tree, CM Haggerty, E Tang, M Fogel, ...
Journal of biomechanics 50, 172-179, 2017
342017
Using a Novel In Vitro Fontan Model and Condition-Specific Real-Time MRI Data to Examine Hemodynamic Effects of Respiration and Exercise
M Tree, ZA Wei, PM Trusty, V Raghav, M Fogel, K Maher, A Yoganathan
Annals of biomedical engineering 46, 135-147, 2018
202018
An in vitro analysis of the PediMag and CentriMag for right-sided failing Fontan support
PM Trusty, M Tree, K Maher, TC Slesnick, KR Kanter, AP Yoganathan, ...
The Journal of Thoracic and Cardiovascular Surgery 158 (5), 1413-1421, 2019
192019
Local hemodynamic differences between commercially available Y-grafts and traditional Fontan baffles under simulated exercise conditions: implications for exercise tolerance
PM Trusty, Z Wei, M Tree, KR Kanter, MA Fogel, AP Yoganathan, ...
Cardiovascular Engineering and Technology 8, 390-399, 2017
152017
In vitro examination of the HeartWare CircuLite ventricular assist device in the Fontan connection
M Tree, PM Trusty, TC Slesnick, A Yoganathan, S Deshpande, K Maher
ASAIO Journal 63 (4), 482-489, 2017
132017
In vitro examination of the ventriflo true pulse pump for failing fontan support
PM Trusty, M Tree, D Vincent, JP Naber, K Maher, AP Yoganathan, ...
Artificial organs 43 (2), 181-188, 2019
122019
A method for In Vitro TCPC Compliance Verification
M Tree, ZA Wei, B Munz, K Maher, S Deshpande, T Slesnick, ...
Journal of Biomechanical Engineering 139 (6), 064502, 2017
112017
Validation of cardiac output as reported by a permanently implanted wireless sensor
M Tree, J White, P Midha, S Kiblinger, A Yoganathan
Journal of Medical Devices 10 (1), 011001, 2016
72016
Fontan geometry and hemodynamics are associated with quality of life in adolescents and young adults
L Mercer-Rosa, MA Fogel, ZA Wei, PM Trusty, M Tree, E Tang, ...
The Annals of thoracic surgery 114 (3), 841-847, 2022
62022
In vitro examination of the HeartWare Circulite VAD in the Fontan circulation
M Tree, P Trusty, B Munz, M Samuel, T Slesnick, KO Maher, ...
The Journal of Heart and Lung Transplantation 35 (4), S46, 2016
52016
Hemodynamics of the VenusP Valve System™—an in vitro study
H Chen, M Samaee, M Tree, L Dasi, A Yoganathan
Frontiers in Medical Technology 6, 1376649, 2024
2024
Rapid Thrombogenesis Prediction in Covid-19 Patients Using Machine Learning
JL Lee, S Alwajidi, M Tree, A Cristobal, H Zhao
IFIP International Conference on Artificial Intelligence Applications and …, 2023
2023
In Vitro Examination of the PediMag and CentriMag Devices for Failing Fontan Support
PM Trusty, M Tree, K Maher, TC Slesnick, AP Yoganathan, ...
Circulation 138 (Suppl_1), A14597-A14597, 2018
2018
In Vitro Examination of the VentriFlo™ True Pulse Pump for Failing Fontan Support
PM Trusty, M Tree, D Vincent, JP Naber, K Maher, AP Yoganathan, ...
The Journal of Heart and Lung Transplantation 36 (4), S36-S37, 2017
2017
The effect of respiration, exercise, and pulsatility on in vitro Fontan hemodynamics
M Tree
Georgia Institute of Technology, 2017
2017
Anatomic and Hemodynamic Changes in Single Ventricle Patients 3-9 Months After Fontan to the Teenage Years: Insights From Cardiac Magnetic Resonance and Computational Fluid …
MA Fogel, E Kim, M Harris, K Whitehead, M Keller, T Spray, JW Gaynor, ...
Circulation 134 (suppl_1), A13848-A13848, 2016
2016
Aortic Stiffness and Its Relationship to Exercise and Ventricular Volumes After Surgical Reconstruction in Single Ventricle Patients Using Real Time Exercise Cardiac Magnetic …
MA Fogel, E Kim, M Keller, M Harris, K Whitehead, phillip Trusty, M Tree, ...
Circulation 134 (suppl_1), A14546-A14546, 2016
2016
The Direct Effect of Flexible Walls on Fontan Connection Fluid Dynamics
M Tree, K Fagan, A Yoganathan
67th Annual Meeting of the American Physical Society Division of Fluid …, 2014
2014
El sistema no puede realizar la operación en estos momentos. Inténtalo de nuevo más tarde.
Artículos 1–20