Seguir
Sorin Siegler
Sorin Siegler
Dirección de correo verificada de drexel.edu
Título
Citado por
Citado por
Año
ISB recommendation on definitions of joint coordinate system of various joints for the reporting of human joint motion—part I: ankle, hip, and spine
G Wu, S Siegler, P Allard, C Kirtley, A Leardini, D Rosenbaum, M Whittle, ...
Journal of biomechanics 35 (4), 543-548, 2002
33862002
Analysis of lumbar spine and hip motion during forward bending in subjects with and without a history of low back pain
MA Esola, PW McClure, GK Fitzgerald, S Siegler
Spine 21 (1), 71-78, 1996
6451996
The mechanical characteristics of the collateral ligaments of the human ankle joint
S Siegler, J Block, CD Schneck
Foot & ankle 8 (5), 234-242, 1988
5181988
The three-dimensional kinematics and flexibility characteristics of the human ankle and subtalar joints—Part I: Kinematics
S Siegler, J Chen, CD Schneck
4181988
Transforaminal lumbar interbody fusion: the effect of various instrumentation techniques on the flexibility of the lumbar spine
BM Harris, AS Hilibrand, PE Savas, A Pellegrino, AR Vaccaro, S Siegler, ...
Spine 29 (4), E65-E70, 2004
3262004
Kinematic analysis of lumbar and hip motion while rising from a forward, flexed position in patients with and without a history of low back pain
PW McClure, M Esola, R Schreier, S Siegler
Spine 22 (5), 552-558, 1997
2401997
Standardization and Terminology Committee of the International Society of Biomechanics. ISB recommendation on definitions of joint coordinate system of various joints for the …
G Wu, S Siegler, P Allard, C Kirtley, A Leardini, D Rosenbaum, M Whittle, ...
J Biomech 35 (4), 543-548, 2002
2152002
The effect of posterior tibialis tendon dysfunction on the plantar pressure characteristics and the kinematics of the arch and the hindfoot
CW Imhauser, S Siegler, NA Abidi, DZ Frankel
Clinical Biomechanics 19 (2), 161-169, 2004
1572004
Mechanics of the ankle and subtalar joints revealed through a 3D quasi-static stress MRI technique
S Siegler, JK Udupa, SI Ringleb, CW Imhauser, BE Hirsch, D Odhner, ...
Journal of Biomechanics 38 (3), 567-578, 2005
1422005
The three-dimensional kinematics and flexibility characteristics of the human ankle and subtalar joint—Part II: flexibility characteristics
J Chen, S Siegler, CD Schneck
1361988
Passive and active components of the internal moment developed about the ankle joint during human ambulation
S Siegler, GD Moskowitz, W Freedman
Journal of biomechanics 17 (9), 647-652, 1984
1261984
Fabrication of Co–Cr–Mo endoprosthetic ankle devices by means of Selective Laser Melting (SLM)
E Liverani, A Fortunato, A Leardini, C Belvedere, S Siegler, L Ceschini, ...
Materials & Design 106, 60-68, 2016
1212016
Three-dimensional flexibility characteristics of the human cervical spine in vivo
P McClure, S Siegler, R Nobilini
Spine 23 (2), 216-223, 1998
1121998
Simulation of human gait with the aid of a simple mechanical model
S Siegler, R Seliktar, W Hyman
Journal of biomechanics 15 (6), 415-425, 1982
1081982
Biomechanical evaluation of the efficacy of external stabilizers in the conservative treatment of acquired flatfoot deformity
CW Imhauser, NA Abidi, DZ Frankel, K Gavin, S Siegler
Foot & ankle international 23 (8), 727-737, 2002
912002
A six-degrees-of-freedom instrumented linkage for measuring the flexibility characteristics of the ankle joint complex
S Siegler, S Lapointe, R Nobilinit, AT Berman
Journal of biomechanics 29 (7), 943-947, 1996
761996
Effect of posterior capsule tightness on glenohumeral translation in the late-cocking phase of pitching
KM Clabbers, JD Kelly, D Bader, M Eager, C Imhauser, S Siegler, ...
Journal of Sport Rehabilitation 16 (1), 41-49, 2007
742007
Subject-specific models of the hindfoot reveal a relationship between morphology and passive mechanical properties
CW Imhauser, S Siegler, JK Udupa, JR Toy
Journal of biomechanics 41 (6), 1341-1349, 2008
702008
Acoustic catheter with rotary drive
S Adrian, PA Lewin, S Siegler, P Walinsky, RC Hayes
US Patent 5,423,797, 1995
691995
Quantitative measurement of ankle passive flexibility using an arthrometer on sprained ankles
W Liu, S Siegler, L Techner
Clinical biomechanics 16 (3), 237-244, 2001
682001
El sistema no puede realizar la operación en estos momentos. Inténtalo de nuevo más tarde.
Artículos 1–20